SIGMA - Logic Analyzer
SIGMA is a powerful, fast, flexible, user-friendly and cost effective logic analyzer with extremely large event memory, real-time hardware compression and complex trigger logic. Moreover, SIGMA is ready for other debugging features by software updates and add-on modules. SIGMA operates on a USB port and requires no external power supply.
SIGMA has been designed with most important real-life user requirements in mind:
-
Extremely large event memory
-
256 Megabit SDRAM memory is used and further enhanced using a real-time hardware compression which allows for 14 680 064 sample storage or for more than 45 minutes of recording.
-
Flexible input/sample speed options
-
- 16 inputs at 50 MHz (and lower sample speed, division by 2 ... 256)
- 8 inputs at 100 MHz
- 4 inputs at 200 MHz
- 16 inputs - sampling on change of an input signal (asynchronous clock) - trailing, falling or both edges, max. clock speed
is 40 MHz at 1:1 duty
- 15 inputs + 1 synchronous clock input (trailing or falling edge), max. clock speed is 49.9 MHz
-
Complex trigger logic
-
Many various triggering options in the 16 inputs/50 MHz mode:
- Any value or edge on any input condition
- Defined duration of the condition ("longer than" and/or "shorter than")
- Sequence of two different conditions
- 16-bit counter - triggering after N-th occurence of the condition
- Extensive condition definition options using logical functions (N)AND,(N)OR,(N)XOR
Standard triggering options in the 8 inputs/100 MHz and 4 inputs/200 MHz modes - triggering on the input signal edge.
Trigger point can be placed to any position of recorded events from the very beginning to the end.
-
Advanced software
-
- Ready for plugins - both ASIX and user definable, e.g. protocol analyzers (like I2C, SPI, UART, SDRAM, Full-Speed and Low-Speed USB, ...).
- Ready for easy multi-language support (not applicable for plugins).
- Waveforms can be saved and loaded to a computer hard disc.
- Waveforms can be exported to a text file for further processing.
- Waveforms can be printed on a printer.
- Flexible trace definition (any combination of input signals and constant logic levels) and trace representation (signals, buses - binary,
octal, decimal, hexadecimal, ASCII). Input signal can be used in more than one trace.
- UART protocol analyzer
- Flexible control using mouse and keyboard
Personal computer requirements: Windows 98 and higher (XP recommended), Pentium 750MHz or faster CPU, at least 256 MB RAM.
Now with LINUX support (using WINE) - read more...
-
User-friendly device
-
- Easy connection to PC - the comfortable USB interface.
- Low power - no power supply adaptor needed.
- Logic probe mode - SIGMA displays momentary logic levels on all 16 inputs.
- Detailed LED indication for instant and intuitive status checking.
- Fast operation - less than 1 second delay for any selected view. (Full data download takes about 90 seconds).
- Input threshold level is suitable for TTL, LVTTL and 2.7 to 5.5V CMOS levels
- Replaceable input buffers - DIP parts in socket allow for easy replacement, if ...
(you know well what happens to any electronic designer sometimes :-)
- Upgradability - due to flexible design based on Xilinx FPGAs it will be possible to upgrade and enhance SIGMA functionality by simple
software update (e.g. frequency, period and duty cycle measurement)
- Small, lightweight and compact.
-
More than logic analyzer
-
Additional debugging features will be available by software upgrades and add-on modules.
Existing software utility for SIGMA:
- Frequency measurement - four independent channels with filtering and averaging
|
|
Larger image
€ 298.-
More about SIGMA price...
What is a "logic analyzer"?
A logic analyzer displays signals in a digital circuit that are too fast to be observed by a human being. A logic analyzer captures digital data from a digital system that has too many channels to be examined with an oscilloscope and presents it to a user so that the user can more easily check correct operation of the digital system.
Source:
Wikipedia
Features
- Extremely large event memory
- Up to 200 MHz sample speed
- Up to 16 inputs
- Flexible trigger options
- "Logic probe" mode
- Well-arranged LED mode indication
- Controlled and powered by USB
- Advanced software
(for both Windows and Linux)
Contents
- SIGMA logic analyzer
- Target cables
- flying wires - 20-pin header (16 channels) - 10-pin header (8 and 4 channels)
- USB cable (A-B)
- Software (CD-ROM)
- User's Manual
Optional add-on
-
PicoHook10 - set of 10 miniature test hooks (2,54 mm = 0,1" width).
Their colors correspond to the colors of the target application cable (brown, red, orange, yellow, green, blue, violet, gray, white
and black).
|
|
Download
Software
- 2008-04-07
-
SIGMA Logic Analyzer Version: 1.07
STFMerge version: 1.0
SIGMA Frequency Measuring version: 1.1
SIGMA Configuration Utility version: 1.1
SIGMA Insider: 0.92 Beta 1
- Fixed: Insider: Start and stop conditions "data rise/fall when clock low/high"
in synchronous mode did not work when using "stream fields".
- 2008-02-27
-
SIGMA Logic Analyzer Version: 1.06
STFMerge version: 1.0
SIGMA Frequency Measuring version: 1.1
SIGMA Configuration Utility version: 1.1
SIGMA Insider: 0.91 Beta 1 (newly added into package)
- Added: Logic Analyzer: I2C Bus plugin
- Fixed: Logic Analyzer: UART plugin access violation at large tests
- 2007-12-03
-
Sigma Logic Analyzer Version: 1.05
STFMerge version: 1.0
Sigma Frequency Measuring version: 1.1
Sigma Configuration Utility version: 1.1
- Added: LINUX support (using WINE) - more...
- Fixed: Logic Analyzer: Asynchronous clock mode clock edge was incorrect
- Added: Logic Analyzer: Asynchronous clock mode sampling changed
- Fixed: Logic Analyzer: UART plugin framing error inside data bits displayed incorrectly
- Fixed: Logic Analyzer: UART plugin data format (ASCII/hex/dec) did not work
- Added: Logic Analyzer: UART plugin data sampling more than once per bit
- 2007-09-13
-
Sigma Logic Analyzer Version: 1.04
STFMerge version: 1.0
Sigma Frequency Measuring version: 1.0
Sigma Configuration Utility version: 1.0
- Fixed: Logic Analyzer: Trigger Out in CMOS mode did not work.
- 2007-07-17
-
Sigma Logic Analyzer Version: 1.03
STFMerge version: 1.0
Sigma Frequency Measuring version: 1.0
Sigma Configuration Utility version: 1.0
- Added: Logic Analyzer: Trigger dialog checks for event length overflow
- Added: Logic Analyzer: Trigger event length counter enlargened to 2^32
(2^16 prescaler + 2^16 true counter) (counter was only 2^16 without prescaler)
- Added: Logic Analyzer: Bus Hint plugin - shows bus label in mouse tooltip while moving above
- Fixed: Logic Analyzer: Wrong trigger event length computing when running at other speed than 50MHz
- 2007-06-13
-
Sigma Logic Analyzer Version: 1.02
STFMerge version: 1.0
Sigma Frequency Measuring version: 1.0
Sigma Configuration Utility version: 1.0
- Fixed: Logic Analyzer: Export current view didn't work when test was previously cropped
- 2007-04-18
-
Sigma Logic Analyzer Version: 1.01
STFMerge version: 1.0
Sigma Frequency Measuring version: 1.0
Sigma Configuration Utility version: 1.0
- Added: Logic Analyzer: Pin view in synchronous clock mode shows clock frequency
- Fixed: Logic Analyzer: Trigger didn't work in synchronous clock mode
- 2007-04-12
- First official release, all versions of included software set to "1"
Documentation
Drivers
Prices
| SIGMA |
€298.- |
| SIGMACAB (additional/replacement target application cable) |
€25.- |
|
PicoHook10 (set of 10 test hooks)
|
€48.- (1 set)
€42.- (2+ sets)
|
VOLUME DISCOUNTS AVAILABLE: The above price is valid for quantities up to 4 pieces.
Please, refer to the Price List to learn about volume discounts.
These prices do not include local taxes (typically VAT), import duties (or similar fees) and shipping costs.
Please note that distributors may have different prices.
Additional information for customers from the EU is available.
The prices in US Dollars or other currencies depend on current EUR/USD exchange rate.
Related products
PRESTO - very fast and flexible USB In-Circuit Serial programmer
PVK40 - feature rich development board for the PIC Flash MCUs
|